Zailaf's Micro data center Rack Cooler 48VDC is a new generation solution, It is highly integrated modular and smart data center solution. It uses racks as the datacenter carrier and fully integrates all sub-systems including UPSs, cooling, power distribution, lightning protection, fire control (optional), wiring, airflow management, intelligent monitoring, and more. It is modular datacenter solution and its offers a data center environment that provides safe equipment operations within the racks, and supports the development and standardizing of micro datacenters that fit into racks. In addition, It takes up very little space, allowing quick deployment within a limited space, and it provides 12 types of solutions that require 20kVA power supply capabilities. This Solution Package is perfect for Schools and Business Data Rooms where space is limited.

Perticular Unit RMC 2.0KW RMC 3.5KW RMC 5.2KW RMC 7.0KW
Total Capacity Watt 2000 3500 5200 7000
SHF 0.9 0.9 0.9 0.9
Ambient Temperature deg C 45 45 45 45
Rack Return Temperature deg C 35 35 35 35
Rack Supply Temperature deg C 20 20 20 20
Power Consumption Watt 1000 1350 2000 2400
Air Flow Cubic Meter/Hour 500 700 1100 1400
Working temperature deg C -5 ~ 55 -5 ~ 55 -5 ~ 55 -5 ~ 55
Out door Protection IP54 IP54 IP54 IP54
Indoor Weight KG 25 25 35 35
Outdoor Weight KG 70 70 75 75
Color RAL7035 RAL7035 RAL7035 RAL7035 RAL7035
Powder Coating Micron 60~80 60~80 60~80 60~80
Noise Indoor dbA 60 60 60 60
Noise Outdoor dbA 70 70 70 70
Voltage +/- 10% VDC 48 48 48 48
Application Rack Cooler, Telecom Rack Cooler, Telecom Rack Cooler, Telecom Rack Cooler, Telecom
Mounting Bottom of Rack 5U Bottom of Rack 5U Bottom of Rack 8U Bottom of Rack 8U
Refrigerant R410a R410a R410a R410a
Dimension Outdoor cabinet
Height mm 650 650 650 650
Width mm 1000 1000 1000 1000
Depth mm 400 400 400 400
Flange Dimension indoor mm 15 15 15 15
Control System
Type Analogue Analogue Analogue Analogue
Display 7-Segment 7-Segment 7-Segment 7-Segment
Make Zailaf Zailaf Zailaf Zailaf
Communication RS485 RS485 RS485 RS485
Alarm HP,LP, Fan fail HP,LP, Fan fail HP,LP, Fan fail HP,LP, Fan fail
Protection Under Voltage, Over Voltage Under Voltage, Over Voltage Under Voltage, Over Voltage Under Voltage, Over Voltage
** Energy consumption under normal conditions.
Data Center Rack Cooler 48VDC
Manufacturer reserves the right to change specifications without prior notice.